Nonmetal ultrasonic detector
Nonmetal ultrasonic detector

CJ-10

Testing of building foundation piles by cross-hole sonic logging.

Get Wholesale Price
Category: STRUCTURAL INSPECTION AND MONITORING

Application

·Testing of building foundation piles by cross-hole sonic logging.

·Inspection of concrete defects by ultrasonic method, such as uncompacted, cellular, hole area.

·Detecting defects of one hole by one trigger two receive.

·Testing dynamic performance of geotechnical investigation, rock, concrete, etc.


Features

·High efficient testing. Lifting speed is more than 60m/s. (20 cm distance).

·Display the test data graphically. User can watch analyze result directly.

·Fast and precise Automatic judge the sound parameters. Real-time wave display to assure test efficiency.

·Humanized software design. Software design apply to User and construction plant. its help information ensure user handle easily.

·Linking the rebound apparatus directly. Detecting strength of concrete by ultrasonic-rebound combine method with linking rebound apparatus directly, and get strength of concrete in time. The functions apply for national patent.

·Being sensitive to receiving signal. Can receive signal more than 10m in concrete without defects.

·Can supply smooth power for radial energy transducer needless external power.

·Standard U等 storage with big capacity.

·Interior lithium battery supply power for apparatus work more than 6 hours.

·Portable, small, light apparatus (1.75Kg).

·Extending function for testing thickness of concrete by impacting echo method.

·Professional and powerful analysis software on windows system. It can export the data to Excel or word for advanced analysis.


TECHNICAL PARAMETERS


Main Control Unit: High-performance Embed Computer

Display: 640×480High brightness TFT Panel

Input: Keyboard

Storage: 1G(Internal)+2G(U-Disk)

Interface: U等

Receive Channel: One

Max Sample Data length: 64k

Trigger Mode: Continuous Trigger, External Trigger

Trigger Voltage(V): 65, 125, 250, 500, 1000 selectable

Receive sensitivity: ≤30μv

Amplifier gain: 82dB

Amplifier bandwidth: 5kHz~500 kHz

Sample Periods: 0.05μs~6.4μs, 8 grades electable

Sound time accuracy: 0.05μs

Amplifier resolution: 0.39%

Power: Interior lithium battery, work more than 6 hours

            External lithium battery, work more than 6 hours (selectable)

            DC 12V

            AC 100V~240V, 50/60Hz

Size: 260 mm×185 mm×60 mm

Weight: 1.75 kg(include lithium battery)

Temperature: -10℃~+40℃